{"product_id":"dtm06-12sa-2xdb9-cable","title":"DTM06-12SA-DB9\/DB9 Adapter Cable for CANedge IP67 Enclosure","description":"\u003cp dir=\"ltr\"\u003eThe DTM06-12SA-DB9\/DB9 adapter lets you continue using standard DB9 adapter cables when your CANedge data logger is installed in an \u003ca href=\"https:\/\/www.gridconnect.com\/collections\/css-electronics-aps\/products\/ip67-enclosure-kit\" title=\"IP67 enclosure kit for CANedge\"\u003eIP67 enclosure\u003c\/a\u003e. The adapter converts the enclosure’s sealed DTM06-12SA connector into two DB9 male connectors that match the CANedge CH1 and CH2 pinouts.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eProtect the logger, keep your cable options\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThe IP67 enclosure makes the CANedge dust-tight and waterproof, with a single DTM06-12SA connector on the outside. While a custom wiring harness for that port can be built, in most deployments, reusing your existing DB9 adapter cables is faster.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThis adapter restores both DB9 interfaces outside the enclosure, allowing CANedge DB9 adapter cables to plug in directly, with no rewiring.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eBuilt for field installations\u003c\/h3\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eSealed DTM06-12SA connection at the IP67 enclosure\u003c\/li\u003e\n\u003cli\u003eOvermolded DB9 connectors for flexibility and durability\u003c\/li\u003e\n\u003cli\u003e1.5 m cable with 22 AWG (0.50 mm²) conductors\u003c\/li\u003e\n\u003cli\u003eOperating range of -20 °C to +80 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eDTM06-12SA-DB9\/DB9 pinout\u003c\/h3\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cstrong\u003e Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cstrong\u003eDB9 Male CH1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cstrong\u003eDB9 Male CH2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cstrong\u003eDTM06-12SA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e5V Supply Output\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003eLIN2 VBAT\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e9\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eGND\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e3, 6\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eGND\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e3, 6\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eVCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e9\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eVCC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e9\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eCAN1-L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eCAN1-H\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eLIN1 Data\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eCAN2-L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eCAN2-H\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cspan\u003eLIN2 Data\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 25%;\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 dir=\"ltr\"\u003eTypical application: mixed heavy-duty fleets\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eAftermarket telematics projects often deploy CANedge units across mixed heavy-duty fleets, where each vehicle type uses a different connector. With this adapter, one IP67 enclosure setup works across the whole fleet. Simply swap the DB9 adapter cable for each vehicle instead of building a custom harness for each connector type.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat you need\u003c\/h3\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eA \u003ca href=\"https:\/\/www.gridconnect.com\/collections\/canedge-series\" title=\"CANedge series\"\u003eCANedge data logger\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eThe \u003ca href=\"https:\/\/www.gridconnect.com\/collections\/css-electronics-aps\/products\/ip67-enclosure-kit\" title=\"IP67 enclosure kit for CANedge\"\u003eCANedge IP67 enclosure\u003c\/a\u003e (required; the adapter mates with its DTM06-12SA connector)\u003c\/li\u003e\n\u003cli\u003eCANedge DB9 adapter cables that match your vehicle or machine connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eInstallation note:\u003c\/strong\u003e \u003cem\u003eThe DTM06-12SA connector is IP67 rated. The DB9 connectors are not. For long-term outdoor or high-humidity installations, protect the DB9 connections or inspect the cables periodically.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border-bottom: 1px solid #e0e0e0; padding: 14px 0;\" open=\"\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eAre the DB9 connectors IP67 rated?\u003cbr\u003e\u003c\/summary\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eNo. Only the DTM06-12SA connector is IP67 rated. Short- to medium-term exposure to light dust and humidity rarely affects the DB9 connectors. For long-term installations, protect the DB9 connections or monitor the cables for replacement.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #e0e0e0; padding: 14px 0;\" open=\"\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eDo I need the CANedge IP67 enclosure to use this adapter?\u003c\/summary\u003e\n\u003cp dir=\"ltr\"\u003eYes. The adapter is designed specifically for the IP67 enclosure and connects to its DTM06-12SA port. It does not plug directly into a CANedge.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #e0e0e0; padding: 14px 0;\" open=\"\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eWhich DB9 adapter cables work with it?\u003cbr\u003e\u003c\/summary\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eAny CANedge DB9 adapter cable. The two DB9 male connectors follow CiA 303-1 and match the CANedge CH1 and CH2 pinouts, so existing cables work as they would on a standalone CANedge.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #e0e0e0; padding: 14px 0;\" open=\"\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eCan I use the H-MTD and MATEnet ports at the same time?\u003cbr\u003e\u003c\/summary\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eNo. Only 1 SPE port is active at a time, selected by DIP switch or USB command. Switching between the ports from a script is a simple way to simulate a link failure during automated testing.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #e0e0e0; padding: 14px 0;\" open=\"\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eWhich protocols does it support?\u003cbr\u003e\u003c\/summary\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe adapter supports high-speed CAN per ISO 11898-2, including CAN FD (Flexible Data-rate), SAE J1939, and NMEA 2000. It also carries LIN (Local Interconnect Network) data lines for both channels on DB9 pin 4.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #e0e0e0; padding: 14px 0;\" open=\"\"\u003e\n\u003csummary style=\"cursor: pointer; font-weight: 600;\"\u003eDoes the adapter carry power to the CANedge?\u003cbr\u003e\u003c\/summary\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eYes. Supply voltage (VCC) runs from DTM06-12SA pins 5 and 6 to CH1 DB9 pin 9, matching the CANedge CH1 pinout. CH2 provides a 5 V supply output on pin 1.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"CSS Electronics ApS","offers":[{"title":"Default Title","offer_id":45787868692503,"sku":"GC-CSS-DTM06-12SA-DB9-DB9-CABLE","price":82.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0026\/8579\/6388\/files\/DTM06-12-pin-db9-adapter-cable.jpg?v=1792524410","url":"https:\/\/www.gridconnect.com\/products\/dtm06-12sa-2xdb9-cable","provider":"Grid Connect","version":"1.0","type":"link"}