IPEH-004005 - MU-Thermocouple1 CAN FD: J: -210 to +1121 °C

$749.00

Leave a review

SKU: GC-CAN-MU-THERMOCOUPLE-J-FD

MPN: IPEH-004005-J

Manufacturer: Peak System Technik

Delivery: Ships within 7-14 business days
Qualifies for Free shipping to the continental US

Temperature Range

Product Information

Product Description

Authorized North America Distributor Stamp

With the MU-Thermocouple1 CAN FD, measurement data of thermocouples is captured, preprocessed, and transmitted via CAN FD. The temperature is measured via 8 connectors, which are specified for the temperature measuring ranges J, K or T, depending on the product version. Temperatures can be captured in Celsius, Fahrenheit, or Kelvin and processed with an individual scale and offset. The measurement data is then transmitted via CAN FD or classic CAN.

Data processing, message transmission, and LED display are set up with the free Windows software Thermocouple FD Configuration. The configuration created on the computer is transferred via the CAN bus to the MU-Thermocouple1 CAN FD which then runs as an independent CAN node. Multiple devices can be configured independently on a CAN bus.

The configuration requires a PEAK CAN interface.

Order Summary

 

SKU

Temperature Range

Manufacturer Part # (MPN)

GC-CAN-MU-THERMOCOUPLE-J-FD -210°C to +1121°C (-346°F to 2050°F) IPEH-004005-J
GC-CAN-MU-THERMOCOUPLE-K-FD -200°C to +1370°C (-328°F to 2498°F) IPEH-004005-K
GC-CAN-MU-THERMOCOUPLE-T-FD -200°C to +400°C (-328°F to 752°F) IPEH-004005-T

Features

  • 8 Mini sockets for thermocouple types J, K, or T
  • 4 galvanically isolated measuring modules, each with 2 thermocouple sockets of the same type
  • Measurement accuracy: 0.2 % or 1 K
  • Accuracy of the reference temperature sensors at +25 °C ambient temperature: typically ±0.5 K, maximum ±1.0 K
  • Maximum resolution of temperature data: 1/16 °C
  • High-speed CAN connection (ISO 11898-2) for data transfer and configuring
  • Complies with CAN specifications 2.0 A/B and FD
  • CAN FD bit rates for the data field (64 bytes max.) from 25 kbit/s up to 10 Mbit/s
  • CAN bit rates from 25 kbit/s up to 1 Mbit/s
  • NXP TJA1044GT CAN transceiver
  • Galvanic isolation up to 500 V
  • LEDs for measurement channels and power supply
  • Configuration with the Windows® software Thermocouple FD Configuration

Documents and Drivers

Documentation

MU-Thermocouple1 CAN FD User Manual

Downloads

Thermocouple FD Configuration

PEAK-Flash

Specifications

Audio Sample Rate

3Hz

CAN FD

D-Sub (m), 9 pins

Certifications

RoHS, EMC

Controller(s)

Integrated in LPC54618

CPU

LPC54618 (based on Arm® Cortex® M4)

Dimensions

130.5 x 59.5 x 73 mm (W x H x D)

Firmware

Firmware upload: via CAN with PEAK-Flash (PCAN interface required)


Frequency

  • Supported Clock frequencies: 80 MHz, 40 MHz, 20 MHz
  • Clock frequency: 160 MHz

Humidity

15 … 90 %, not condensing, relative

Input/Output

Thermocouple Inputs: 8 x Mini sockets (DIN EN 50212)

Isolation

Galvanic isolation:

  • Inputs: 1A/1B, 2A/2B, 3A/3B, 4A/4B are galvanically decoupled from each other with 500 V;
  • Inputs 1A/1B, 2A/2B, 3A/3B, 4A/4B are galvanically decoupled from the supply with 500 V

Measurement Accuracy

Of the measurement unit: 0.2 % or 1 K

Of the reference temperature sensors:

  • Typically: 0.5 K
  • Maximum values: ±1 K at 0 … 70 °C (32 … 158 °F)
  • ±2 K at -20 … 85 °C (-4 … 185 °F)
  • ±3 K at -40 … 125 °C (-40 … 257 °F)

Measurement Resolution

Max. resolution for CAN data: 1/16 °C

Memory

200 kByte on-chip SRAM

MPN

IPEH-004005-J, IPEH-004005-K, IPEH-004005-T

Power

Phoenix mating connector1, 2-pole, pitch 3.81 mm

Power Consumption

Idle: 75 mA at 12 V

Maximum:

  • 110 mA at 8 V
  • 75 mA at 12 V
  • 35 mA at 30 V

Product Weight

420g

Protocols

Protocols on OSI layer 2: CAN FD ISO 11898-1:2015, CAN FD non-ISO, CAN 2.0 A/B

Security/Protection

  • ±36 V (static) overvoltage protection
  • -36 V reverse polarity protection
  • ±4 kV ESD protection
  • IP20

Sensor(s)

Reference temperature sensors: 4 (1 per measuring module)

Temperature Range

  • J = -210 … +1121 °C (-346 … +2050 °F)
  • K = -200 … +1370 °C (-328 … +2498 °F)
  • T = -200 … +400 °C (-328 … +752 °F)

Termination

Internal: Switchable, not activated on delivery

Transceiver

TJA1044GT

Transmission Speed

Physical: ISO 11898-2 (High-speed CAN)

Voltage

  • Operating: 8 -30 V DC
  • Maximum at pins CAN_H/CAN_L: ± 42 V

Have a Special Request?

Please fill out the information below and our sales team will respond within 1 business day.

What you can expect from Grid Connect:

  • High quality industrial networking and IoT solutions.
  • Hundreds of product options to fit your needs, many available to ship same or next day.
  • Unmatched technical support.
  • Customization options to fit your needs.
  • Price match guarantee on all products.

Please fill out the information below and our sales team will provide a quote within 1 business day.

Customer Reviews