IXXAT CAN-CR300 4 channel CAN/CAN FD Repeater optional bus termination: No Termination

$776.00

Leave a review

SKU: GC-IXT-CR300

MPN: 1.01.0210.40200

Manufacturer: Ixxat

Delivery: Ships within 7-8 weeks
Qualifies for Free shipping to the US

Termination Option

Product Information

Product Description

The Ixxat CAN-CR300 repeater with 4 CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems, and offers galvanic isolation. The flexibility to optimize network structures frees them from CAN bus structure constraints by enabling extended layouts (stub lines, star and tree topologies).

The device can be purchased with or without integrated bus termination resistors. With the termination option (120 Ohm, switchable via DIP switch), the termination resistors prevent reflections on the line ends and ensure optimum communication.

It's designed for industrial environments by meeting high demands for robustness, temperature ranges, and safety. With its fast and transparent operation, there is minimal impact on real-time behavior equivalent to a short line length (ca. 35 m/175 ns delay). With transparent transmission, the repeater is compatible with all higher layer protocols.

Network Reliability

The CAN-CR300 ensures system reliability by electrically isolating CAN/CAN FD segments and power which auto-separates network faults and keeps the network operational. In case of disturbances in the CAN lines, the repeater automatically disconnects the affected segment and restores it after the fault is resolved, ensuring uninterrupted network operation. Network components can be galvanically isolated up to 1 kV. This reliably enhances the protection of the device against damage to electronics caused by voltage peaks.

Combined CAN and CAN FD interfaces in 1 device.

Equipped with 4 CAN/CAN FD channels, the CAN-CR300 can be used to establish a physical coupling and galvanic isolation of two segments of both CAN and CAN FD bus systems.

Application Sample

CAN repeaters can be used to better adapt the cable routing to ambient conditions. Stub lines can be made, and the bus structure can be expanded to a star/tree structure, which saves cable lengths. Shorter cable lengths reduce interference on the signal lines and enable higher bit rates. Segments connected via repeaters are galvanically decoupled, and therefore, offer overvoltage protection for connected participants. 


Order Summary

 

 SKU Termination Resistors Manufacturer Part # (MPN)
GC-IXT-CR300 No 1.01.0210.40200
GC-IXT-CR300-T Yes 1.01.0210.40000

Features

  • Robust industrial use for operation, temperature ranges and safety
  • Fast and transparent operation
  • Flexibility in CAN FD network design
  • Cost savings due to simple wiring
  • Enhanced network reliability
  • Improved network monitoring and fault recovery
  • Increased system protection
  • CAN and CAN FD interfaces combined in 1 device
  • Integrated bus termination resistors optional

Documents and Drivers

Documentation

CAN-CR300 Repeater User Manual

CE - Declaration of Conformity

CAN-CR300 Product Dimensions Diagram

Specifications

Content of Delivery

  • CAN FD repeater
  • User manual

Dimensions (W x H x D)

105 x 114 x 22.5 mm  (4.1 x 4.5 x 0.9 in)

Weight

No termination resistors:  220 g  (0.49 lbs)

With Termination resistors:  170 g  (0.37 lbs)

Mounting

DIN rail mount (bracket included)

Current Consumption

  • Type Value at Vcc Nom (mA):  90
  • Max value at Vcc nom (mA) No Termination Resistors:  125
  • Max value at Vcc nom (mA) With Termination Resistors: 100

Input Voltage (V)

+9 V to +36 V DC 

Isolation

1 kV DC for 1 sec. 

Termperature

  • Operating:   -20°C ~ 70°C (-4°F ~ 158°F)
  • Storage:   -40°C ~ 85°C (-40°F ~ 185°F)
  • Relative Humidity:   10 to 95 %, non-condensing 

Enclosure

IP20, Polyamide housing for top hat rail mounting

Certifications & Standards

  • CE
  • FCC
  • WEEE Category:  IT and telecommunications equipment
  • ETIM Classification:  EC000698
  • Protection Class IP:  IP20

Connectors / Input / Output

4 x screw terminals, 1 x power connector 

CAN Features

  • CAN Mode:   CAN high-speed (ISO 11898-2) with CAN choke 
  • CAN Baud Rate:  Up to 1 Mbit/s

CAN/CAN FD Features

  • CAN FD Mode:   ISO CAN FD, nonISO CAN FD
  • CAN FD Baud Rate:    Arbitration rate up to 1000 kBit/s, data rate up to 8000 kBit/s (verified by testing). User defined bit rates are possible. 
  • CAN FD Transceiver:  MCP2562FD

Request a Quote

Curious about bulk pricing? Please fill out the information below and our sales team will provide a quote within 1 business day.

Request a Quote

As a trusted supplier of industrial networking and IoT products for more than 20 years, Grid Connect is your source for new solutions to old problems.

Request a Quote

As a trusted supplier of industrial networking and IoT products for more than 20 years, Grid Connect is your source for new solutions to old problems.

Customer Reviews